Article 55. Safety in electricity transmission, distribution
Law 28/2004/QH11 — Luật Điện lực số 28/2004/QH11
1. Electricity work owners shall have to:
a) Put up electric safety signboards at transformer stations, electric posts;
b) Color-paint and place signal lights on tops of posts of special heights and special positions in order to safely protect the high-voltage electricity grids.
2. At cross-sections between overhead high-voltage transmission lines, underground electric cables and railways, land roads, inland waterways, the placement and management of signboards and “no-cross” signboards for transport means shall comply with the regulations of the Transport Ministry. Owners of the subsequently built- works must bear the costs of placement of signboards and “no-cross” signboards.
3. When handing over electricity transmission works, the work investors must hand to the units managing the operation of the electricity grids all technical documents, pre-acceptance test records, land assignment or land lease decisions and documents related to compensations and ground clearance according to law provisions.
4. Units managing the operation of electricity grids must periodically organize the inspection, technical maintenance and overhaul of electricity grids, ensuring that the systems operate safely according to regulations on electric safety; conduct regular checks, detect and prevent acts of violating the regulations on electric safety, safely protect high-voltage electricity grids and coordinate for implementation of technical solutions and optimal operation in order to reduce electric energy loss in the course of electricity transmission.
5. When repairing or maintaining electricity transmission works, the units managing the operation of electricity grids and units performing the repair or maintenance must fully and strictly follow the order of safety measures prescribed by the regulations on electric safety techniques.
6. The high-voltage transmission line sections running over dwelling houses and/or works where people permanently live or work must be supported with steel or concrete poles, and the electric wires must not have joints in intervals between poles, except for electric wires of cross-section of 240 mm or over, which are permitted to have one joint for one electric phase and must meet other law-prescribed standards on protection of safety of high-voltage electricity grids. The units managing the operation of electricity grids must not overload such transmission lines.
7. Electric cables running underground or lying in the structure of other works or running together with communications lines must be guaranteed with safety distances prescribed by regulations on electric equipment and other relevant law provisions.
8. The lightning-arresting and earthed equipment and systems of the electricity transmission and distribution grids must be installed strictly according to designs, pre-acceptance tested and periodically checked strictly according to electric safety regulations and technical standards.
Article 55, Law 28/2004/QH11